Published lots
Batch number, lab order number, date, report. Search by batch to go straight to a document.
| Batch | Compound | Content measured | Lab order | Report issued |
|---|---|---|---|---|
| Not stated | 5-Amino-1MQ Pellets | 48.78 mg per capsule | 100014501 | 25 May 2026 |
| BPC-C-0426 | BPC-157 Pellets | 431.25 mcg per capsule | 100014503 | 25 May 2026 |
| DIH-0426 | Dihexa Pellets | 10.79 mg per capsule | 100014504 | 25 May 2026 |
| RET-0426 | Retatrutide | 5.74 mg | 100014500 | 25 May 2026 |
| TESO-0426 | Tesofensine Pellets | 526.81 mcg per tablet | 100014502 | 25 May 2026 |
| BPC-0426 | BPC-157 | 5.76 mg | 100013913 | 16 Apr 2026 |
| CJC-0426 | CJC-1295 no DAC | 2.10 mg | 100013908 | 16 Apr 2026 |
| EPI-0426 | Epithalon | 10.74 mg | 100013910 | 16 Apr 2026 |
| IPA-0426 | Ipamorelin | 2.15 mg | 100013912 | 16 Apr 2026 |
| MOT-0426 | MOTS-c | 5.56 mg | 100013911 | 16 Apr 2026 |
| SS3-0426 | SS-31 | 6.44 mg | 100013914 | 16 Apr 2026 |
| SEX-0426 | Semax | 5.90 mg | 100013909 | 16 Apr 2026 |
| TBB-0426 | BPC-157 / TB-500 Blend | TB-500: 5.18 mg BPC-157: 5.46 mg |
100013905 | 16 Apr 2026 |
| TA1-0426 | Thymosin Alpha-1 | 5.20 mg | 100013906 | 16 Apr 2026 |
This table lists documents that exist. Products still waiting on a report show Certificate pending on their page and do not appear here.
Method
A 3 µl injection is made onto a BioBasic 8 Thermo Scientific column and run on a linear water / acetonitrile gradient, both phases modified with 0.1 % trifluoroacetic acid. Identity is confirmed by mass spectrometry against the calculated free-base mass. Each report carries the analysing technician’s name and a verification code.
The laboratory
Analiza Białek sp. z o.o. ul. Duńska 9, 54-427 Wrocław, Poland KRS 0000966168 · NIP 8992922970 · REGON 521751875
Every report carries a lab order number and a verification code. Both can be checked with the laboratory at analizabialek.com/wyniki.
One report, in full
BPC-157, lot BPC-0426, reproduced as the laboratory issued it.
- Laboratory
- Analiza Białek sp. z o.o.
- Batch
- BPC-0426
- Lab order
- 100013913
- Received
- 10 Apr 2026
- Started
- 13 Apr 2026
- Issued
- 16 Apr 2026
- Substance
- BPC-157
- Sample name
- BPC-157
- Sample
- Sample provided by customer
- Form
- White powder in a glass vial
- Content
- 5.76 mg
- Purity
- 99%
- Technician
- mgr Arkadiusz Zając
- Verification
- T5KJ18M6
To check this document with the laboratory, go to analizabialek.com/wyniki and enter lab order number 100013913 with verification code T5KJ18M6, both printed on the report.
Content is the amount the laboratory measured in the sample it received. Where it differs from the strength a product is listed at, both are published as they are.